Difference between revisions of "Atlas:Analysis HC beyond STEP09"
(→Objectives) |
(→Lessons learnt from STEP09) |
||
Ligne 5: | Ligne 5: | ||
== Lessons learnt from STEP09 == | == Lessons learnt from STEP09 == | ||
+ | *Sites may identify reasonable amount of analysis they can assume and set hard limits on number of analysis running jobs | ||
+ | *Balancing data across many disk servers is essential. | ||
+ | *Very high i/o required by analysis (5 MB/s per job). Sites should review LAN architecture to avoid bottlenecks. | ||
+ | |||
== Results == | == Results == | ||
* ATLAS HC Tests results : http://gangarobot.cern.ch/hc/ '''(New web interface!)''' | * ATLAS HC Tests results : http://gangarobot.cern.ch/hc/ '''(New web interface!)''' |
Version du 16:10, 19 octobre 2009
--Chollet 15:56, 19 octobre 2009 (CEST)
Distributed Analysis Stress Tests - HammerCloud beyond STEP09
Sommaire
Lessons learnt from STEP09
- Sites may identify reasonable amount of analysis they can assume and set hard limits on number of analysis running jobs
- Balancing data across many disk servers is essential.
- Very high i/o required by analysis (5 MB/s per job). Sites should review LAN architecture to avoid bottlenecks.
Results
- ATLAS HC Tests results : http://gangarobot.cern.ch/hc/ (New web interface!)
- ATLAS STEP09 summary : http://gangarobot.cern.ch/st/summary.html
ATLAS Info & Contacts
- Information via mailing list ATLAS-LCG-OP-L@in2p3.fr
- LPC : Nabil Ghodbane - Nabil.Ghodbane@cern.ch
- LAL : Nicolas Makovec
- LAPP : Stéphane Jézéquel
- CPPM : Emmanuel Le Guirriec
- LPSC : Sabine Crepe
- LPNHE : Tristan Beau
- CC-T2 : Catherine, Ghita
- IRFU : Nathalie Besson
HC Tests
Objectives
- Improve Cloud readiness by following site&ATLAS problems week by week (SL5 migration, site upgrades)
- Identify best data access method per site by comparing the event rate and CPU/Walltime
https://twiki.cern.ch/twiki/bin/view/Atla/HammerCloudDataAccess#FR_cloud
- Exercise Analysis with Cond DB access and Tag Analysis
Week 40
- Muon Analysis (Release 15.3.1)
- Input DS (STEP09) : mc08.*merge.AOD.e*_s*_r6*tid*
- 3 HC tests of 24 hrs each :
Test 649 via Panda (mode copy-to-WN using rfcp - xrootd in ANALY-LYON)
Test 652/656 via WMS (DQ2_LOCAL mode or direct access dcap/rfio)
Test 653/657 via WMS (FILE_STAGER mode)
Recent talks
- Summary of HammerCloud Tests since STEP09 Dan van der Ster's talk@ATLAS Jamboree T1/T2/T3 (13 October 2009)
- HammerCloud Plans Johannes Elmsheuser's talk@ATLAS S&C Week (2 September 2009)