Atlas:Analysis HC beyond STEP09

Un article de lcgwiki.
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

--Chollet 15:56, 19 octobre 2009 (CEST)

Distributed Analysis Stress Tests - HammerCloud beyond STEP09

Lessons learnt from STEP09

  • Sites may identify reasonable amount of analysis they can assume and set hard limits on number of analysis running jobs
  • Balancing data across many disk servers is essential.
  • Very high i/o required by analysis (5 MB/s per job). Sites should review LAN architecture to avoid bottlenecks.

Results

ATLAS Info & Contacts

  • Information via mailing list ATLAS-LCG-OP-L@in2p3.fr
  • LPC : Nabil Ghodbane - Nabil.Ghodbane@cern.ch
  • LAL : Nicolas Makovec
  • LAPP : Stéphane Jézéquel
  • CPPM : Emmanuel Le Guirriec
  • LPSC : Sabine Crepe
  • LPNHE : Tristan Beau
  • CC-T2 : Catherine, Ghita
  • IRFU : Nathalie Besson

HC Tests

Objectives

  • Improve Cloud readiness by following site&ATLAS problems week by week (SL5 migration, site upgrades)
  • Identify best data access method per site by comparing the event rate and CPU/Walltime

https://twiki.cern.ch/twiki/bin/view/Atla/HammerCloudDataAccess#FR_cloud

  • Exercise Analysis with Conditions DB access (see where squid caching is needed) and Tag analysis

Week 40

  • Muon Analysis (Release 15.3.1)
  • Input DS (STEP09) : mc08.*merge.AOD.e*_s*_r6*tid*
  • 3 HC tests of 24 hrs each :

Test 649 via Panda (mode copy-to-WN using rfcp - xrootd in ANALY-LYON)
Test 652/656 via WMS (DQ2_LOCAL mode or direct access dcap/rfio)
Test 653/657 via WMS (FILE_STAGER mode)